155 lines
6.2 KiB
Python
155 lines
6.2 KiB
Python
"""GatewayRuntime (Task 18 F4 capstone): builds and owns the write/active-read/gRPC
|
|
object graph and wires it into the app's lifecycle.
|
|
|
|
Reuses the existing ingestor's logger/notification_handler/metrics_controller and
|
|
its already-connected DataManager (so CertProvider shares the existing Mongo
|
|
connection instead of opening a second one -- MongoDBRepository.find_one has the
|
|
exact (collection_name, filters, metadata) signature CertProvider.fetch calls).
|
|
|
|
# ponytail: subscription v2 swap + scheduled_tick wiring happen at 1974
|
|
# integration; when swapping, build ONE SubscriptionEngine per OPC server (its
|
|
# non_receive_count is engine-wide -- see plan ledger F1 carry-forward).
|
|
"""
|
|
|
|
from os import getenv
|
|
|
|
from sientia_do.notifications.handlers import CoreNotificationHandler as NotificationHandler
|
|
from sientia_do.notifications.models import NotificationLevel
|
|
from sientia_do.observability.logger import Logger
|
|
from sientia_do.observability.metrics_controller import MetricsController
|
|
from sientia_do.observability.sientia_monitoring import SientiaMonitoring
|
|
from sientia_do.repository.minio_repository import MinioRepository
|
|
from sientia_do.temporal.activities.postgres import Postgres
|
|
from sientia_do.utils.connectors_config import build_postgres_config
|
|
|
|
from ingestor.adapters.grpc_server import GrpcServer
|
|
from ingestor.adapters.nats_consumer import NatsWriteConsumer
|
|
from ingestor.config import GatewayConfig, _env_bool
|
|
from ingestor.connection.certs import CertProvider
|
|
from ingestor.connection.pool import OpcConnectionPool
|
|
from ingestor.engines.active_read import ActiveReadEngine
|
|
from ingestor.engines.write import WriteEngine
|
|
from ingestor.io.data_sink import DataSink
|
|
from ingestor.managers.data_manager import DataManager
|
|
|
|
|
|
class GatewayRuntime(SientiaMonitoring):
|
|
"""Owns the gateway write/active-read/gRPC object graph. Resilient to NATS
|
|
being unreachable at startup: the read path (existing subscription loop,
|
|
gRPC on-demand reads) must keep working even if the write path can't
|
|
connect yet -- so a NATS connect failure is logged/notified, not raised,
|
|
and retried from `idle_sweep()` on each main-loop iteration."""
|
|
|
|
def __init__(
|
|
self,
|
|
config: GatewayConfig,
|
|
data_manager: DataManager,
|
|
logger: Logger,
|
|
notification_handler: NotificationHandler,
|
|
metrics_controller: MetricsController,
|
|
metadata: dict | None = None,
|
|
):
|
|
SientiaMonitoring.__init__(self, logger, notification_handler, metrics_controller)
|
|
self.config = config
|
|
self.metadata = metadata or {}
|
|
self._nats_started = False
|
|
self._nats_notified = False # notify once per outage, not per 5s retry
|
|
|
|
minio = MinioRepository(
|
|
endpoint=getenv('MINIO_ENDPOINT', 'localhost:9000'),
|
|
access_key=getenv('MINIO_ACCESS_KEY', 'minioadmin'),
|
|
secret_key=getenv('MINIO_SECRET_KEY', 'minioadmin'),
|
|
secure=_env_bool('MINIO_SECURE', True),
|
|
bucket=config.cert_bucket,
|
|
logger=logger,
|
|
notification_handler=notification_handler,
|
|
metrics_controller=metrics_controller,
|
|
)
|
|
cert_provider = CertProvider(
|
|
mongo=data_manager.mongo_repository,
|
|
minio=minio,
|
|
cache_dir=config.cert_cache_dir,
|
|
bucket=config.cert_bucket,
|
|
metadata=self.metadata,
|
|
)
|
|
self.pool = OpcConnectionPool(cert_provider, logger, notification_handler, metrics_controller)
|
|
|
|
postgres = Postgres(
|
|
**build_postgres_config(),
|
|
logger=logger,
|
|
notification_handler=notification_handler,
|
|
metrics_controller=metrics_controller,
|
|
)
|
|
self.sink = DataSink(data_manager, postgres)
|
|
|
|
self.write_engine = WriteEngine(
|
|
self.pool,
|
|
self.sink,
|
|
logger,
|
|
notification_handler,
|
|
metrics_controller,
|
|
write_timestamp=config.write_timestamp,
|
|
write_quality=config.write_quality,
|
|
min_pause_s=config.write_min_pause_s,
|
|
)
|
|
self.nats_consumer = NatsWriteConsumer(
|
|
config.nats_url,
|
|
self.write_engine,
|
|
logger,
|
|
subject=config.nats_write_subject,
|
|
queue=config.nats_queue,
|
|
)
|
|
self.active_read = ActiveReadEngine(
|
|
self.pool, self.sink, logger, notification_handler, metrics_controller
|
|
)
|
|
|
|
# slot_lookup=None for now: address -> names resolution needs slot v2
|
|
# (1974); until then ReadTag responses just aren't persisted.
|
|
self.grpc_server = (
|
|
GrpcServer(self.active_read, logger, port=config.grpc_port, slot_lookup=None)
|
|
if config.grpc_enabled
|
|
else None
|
|
)
|
|
|
|
async def start(self) -> None:
|
|
await self._start_nats()
|
|
if self.grpc_server is not None:
|
|
await self.grpc_server.start()
|
|
self.logger.info(
|
|
f'GatewayRuntime started: nats_started={self._nats_started} '
|
|
f'grpc_enabled={self.grpc_server is not None}'
|
|
)
|
|
|
|
async def stop(self) -> None:
|
|
if self.grpc_server is not None:
|
|
await self.grpc_server.stop()
|
|
if self._nats_started:
|
|
await self.nats_consumer.stop()
|
|
self._nats_started = False
|
|
await self.pool.close_all()
|
|
|
|
async def idle_sweep(self) -> None:
|
|
await self.pool.release_idle(self.config.idle_conn_max_s)
|
|
if not self._nats_started:
|
|
await self._start_nats()
|
|
|
|
async def _start_nats(self) -> None:
|
|
if self._nats_started:
|
|
return
|
|
try:
|
|
await self.nats_consumer.start()
|
|
self._nats_started = True
|
|
self._nats_notified = False
|
|
except Exception as e:
|
|
self.logger.error(f'GatewayRuntime: failed to start NATS write consumer: {e}')
|
|
if self._nats_notified:
|
|
return
|
|
self._nats_notified = True
|
|
await self.send_notification_async(
|
|
metadata=self.metadata,
|
|
notification_id='GATEWAY_NATS_CONSUMER_START_FAILED',
|
|
message=f'Failed to start NATS write consumer: {e}',
|
|
block='gateway_runtime',
|
|
level=NotificationLevel.ERROR,
|
|
)
|