The Orchestrator now writes the slot v2 (contract C1) the OPC Gateway reads:
one entry per (server, address) with a names[] list, so an address read by N
pipelines is read once and written to N collections (fixes "one name per
address", where the second model's scouter discarded everything).
- O1: load connectors (opc_ua, Active) and connector_tags (Read, Active) in
parallel with the current loads. Queries are optional in the input with
defaults in code (D9); empty or missing collections load nothing. The loads
sit behind workflow.patched('SIENTIAPDE-1974-tag-database'), so a run in
flight during a deploy replays without them.
- O2: gather_read_tags groups by (server, address). A read tag with tag_id
resolves address/connector from connector_tags and the server from connectors
(RF3); without tag_id it keeps server_id + tag_address + opc-servers (RF4),
so every environment without a tag database keeps collecting (P4).
- O3/SC1: resolve_tag_names is the single source of tag names for both the
scouter's model_tags and the slot's names[].
- O4: build_tag_config emits server_id/name/url/server_uri/use_security/
subscription_period_ms + tags{frequency, active_read, names}; no certificate
paths (the gateway takes the certificate from MinIO). frequency = lowest
among pipelines; subscription period = connector value, else min/2 as before;
active_read off unless a pipeline enables it (lowest cycle_multiple, D3).
- O5: process_slots splits by address (names of an address never split) and
notifies, once per run, unknown tag_id, missing/inactive connector and
unknown opc-servers server_id.
- O6: create_slot_config writes only new or changed slots; the slot is built
in a stable order, so unchanged pipelines do not make the gateway
re-subscribe (and the "Inserted slots" report stops firing every run).
- O7: unit tests for multi-name, repeated address, unknown tag_id, inactive
connector, mixed tags, server-name clash, active_read, slot division,
stability, SC1 and the replay path (184 tests).
- O8: README documents the slot v2 contract and the new optional inputs.
- test_email.test_close: count only the instance under test; an Email left by
another test can be garbage-collected (Email.__del__ -> close) while the
patch is active, which the new tests' allocation pattern exposed.
Dry run with the dev data (scouter-sin-approx): the v2 slot is equivalent to
the current v1 slot as seen by the gateway's parse_slot (same server, addresses,
collections, names, frequency and subscription period).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>