Files
sientia-dataops-orchestrato…/CLAUDE.md
Eduardo Rios efa0d9411b SIENTIAPDE-1974: feat(slots): write the OPC slot v2 from pipelines and the tag database
The Orchestrator now writes the slot v2 (contract C1) the OPC Gateway reads:
one entry per (server, address) with a names[] list, so an address read by N
pipelines is read once and written to N collections (fixes "one name per
address", where the second model's scouter discarded everything).

- O1: load connectors (opc_ua, Active) and connector_tags (Read, Active) in
  parallel with the current loads. Queries are optional in the input with
  defaults in code (D9); empty or missing collections load nothing. The loads
  sit behind workflow.patched('SIENTIAPDE-1974-tag-database'), so a run in
  flight during a deploy replays without them.
- O2: gather_read_tags groups by (server, address). A read tag with tag_id
  resolves address/connector from connector_tags and the server from connectors
  (RF3); without tag_id it keeps server_id + tag_address + opc-servers (RF4),
  so every environment without a tag database keeps collecting (P4).
- O3/SC1: resolve_tag_names is the single source of tag names for both the
  scouter's model_tags and the slot's names[].
- O4: build_tag_config emits server_id/name/url/server_uri/use_security/
  subscription_period_ms + tags{frequency, active_read, names}; no certificate
  paths (the gateway takes the certificate from MinIO). frequency = lowest
  among pipelines; subscription period = connector value, else min/2 as before;
  active_read off unless a pipeline enables it (lowest cycle_multiple, D3).
- O5: process_slots splits by address (names of an address never split) and
  notifies, once per run, unknown tag_id, missing/inactive connector and
  unknown opc-servers server_id.
- O6: create_slot_config writes only new or changed slots; the slot is built
  in a stable order, so unchanged pipelines do not make the gateway
  re-subscribe (and the "Inserted slots" report stops firing every run).
- O7: unit tests for multi-name, repeated address, unknown tag_id, inactive
  connector, mixed tags, server-name clash, active_read, slot division,
  stability, SC1 and the replay path (184 tests).
- O8: README documents the slot v2 contract and the new optional inputs.
- test_email.test_close: count only the instance under test; an Email left by
  another test can be garbage-collected (Email.__del__ -> close) while the
  patch is active, which the new tests' allocation pattern exposed.

Dry run with the dev data (scouter-sin-approx): the v2 slot is equivalent to
the current v1 slot as seen by the gateway's parse_slot (same server, addresses,
collections, names, frequency and subscription period).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-06 15:44:07 -03:00

8.0 KiB

CLAUDE.md

This file provides guidance to Claude Code (claude.ai/code) when working with code in this repository.

Project

SIENTIA DataOps Orchestrator — a Temporal.io workflow application for pipeline orchestration, real-time alerting, and scheduled reporting on the SIENTIA platform. Python 3.11+, package name orchestrator.

Commands

Install deps:

pip install -r requirements.txt
pip install -r requirements-dev.txt   # ruff, mypy, bandit, pytest, pytest-cov, pytest-asyncio

Run the worker locally (activates venv, loads .env, runs python -m orchestrator.worker.worker):

./run_local.sh

Tests:

pytest tests/ --cov=orchestrator --cov-report=html   # full suite with coverage
pytest tests/orchestrator/activities/test_mongo_db.py  # single file
pytest tests/orchestrator/activities/test_mongo_db.py::TestClass::test_name  # single test
./run_coverage.sh   # runs pytest w/ coverage, opens htmlcov/index.html

Lint/format/type/security (run individually — validate.sh referenced by README no longer exists in the repo, so don't rely on it):

ruff format --check orchestrator/ tests/
ruff check orchestrator/ tests/
mypy orchestrator/
bandit -r orchestrator/ -ll

# autofix
ruff format orchestrator/ tests/
ruff check --fix orchestrator/ tests/

CI quality gate (.github/workflows/quality-gate.yml) calls the shared reusable workflow Aignosi/github_workflow_templates/.github/workflows/dataops-module-quality-gate.yml on PRs to main — it's the source of truth for what must pass, not a local script.

Architecture

Layering

  • orchestrator/worker/worker.py — entrypoint (python -m orchestrator.worker.worker). Builds a single Activities instance, connects to Temporal, starts Prometheus (HTTP_METRICS_PORT) and Temporal SDK metrics (HTTP_SDK_METRICS_PORT) servers, then runs three Workers concurrently via asyncio.gather, each on its own task queue: orchestrator-queue, alerts-queue, reports-queue. prepare_worker.py derives the queue name from the workflow class name (camel_to_snake) and reads per-queue concurrency/poller tuning from env vars prefixed with the workflow name (e.g. ORCHESTRATOR_MAX_CONCURRENT_ACTIVITIES).
  • orchestrator/workflows/ — Temporal workflow definitions: orchestrator.py (pipeline/slot/schedule orchestration), alerts.py (real-time ERROR notifications), reports.py (scheduled all-level reports). alerts.py and reports.py both delegate to the same two subworkflows in workflows/subworkflows/: load_notification_package.py (load notifications + receiver configs from Mongo, incremental via Redis timestamp) and process_notifications.py (build HTML email, send, log to Postgres). The difference between alerts and reports is which filter activity they call (filter_notification_alerts vs filter_notification_reports) and their base data filter (level: ERROR by default vs all levels) — load_notification_package.py's _compute_query_time_filter can widen either beyond that default to the union of active receiver groups' own levels (SIENTIAPDE-2011); the ERROR-only default only holds when no active group narrows further. Receiver groups also support a model_ids allow-list (SIENTIAPDE-2149), independent of the pre-existing ignore_models_id deny-list — both apply together (AND) when a group configures both, and model_ids follows the same union-at-query-time / precise-per-group-slice split as levels. load_latest_data's Mongo query is capped at NOTIFICATION_QUEUE_BATCH_SIZE documents per run (default 0, meaning unlimited — unchanged from pre-SIENTIAPDE-2013 behavior unless a deployment opts in), sorted by timestamp ascending so a capped run always returns the oldest pending batch first (SIENTIAPDE-2013) — a hard cap with no drain loop, since the incremental Redis cursor picks up any remainder on the next run.
  • orchestrator/activities/activities.py — Activities is a single class combining every activity mixin via multiple inheritance: TemporalManager, SlotManager, Formatters, MongoDB, Email, Postgres (Postgres comes from sientia_do.temporal.activities.postgres, the external sientia-dataops-library dependency). One instance is constructed in worker.py and its bound methods are handed to each Worker as the activity list — activities are plain methods on this shared object, not separate classes. Each mixin's __init__ takes its own config dict plus shared logger, notification_handler, metrics_controller. Activities.shutdown() closes every mixin's connections.
  • orchestrator/utils/ — connectors_config.py builds each config dict from env vars (Temporal/Redis/MongoDB/Postgres/Email); email_builder.py renders Jinja2 templates (utils/templates/email_template.html, general_template.html); orchestrator_functions.py transforms pipeline documents into pipeline-type-specific configs (scouter, pi_web_api_scouter, predictions_batch, minimal_retrain, drift, simple_metrics) and builds the OPC slot v2 the gateway reads (gather_read_tags / build_tag_config, contract C1: one entry per address with a names[] list, tags resolved through the tag database when they carry a tag_id; see the README section "OPC slots"). resolve_tag_names is the single source of tag names for both the scouter's model_tags and the slot's names (SIENTIAPDE-1974 SC1); converters.py handles Temporal schedule frequency parsing.

Temporal-specific conventions (all workflow/activity files follow this)

  • Every workflow and activity-consuming module wraps non-deterministic/side-effecting imports in with workflow.unsafe.imports_passed_through(): ... right after from temporalio import workflow, because Temporal's sandbox restricts what workflow code can import directly. When adding a new workflow file, follow the existing pattern (see orchestrator/workflows/orchestrator.py, orchestrator/activities/activities.py) rather than importing at module top level.
  • Workflows are registered with @workflow.defn(name='...'); the run method is @workflow.run. Activity calls from within a workflow go through workflow.start_local_activity_method / workflow.execute_activity_method referencing Activities.<method> (the class method, not an instance) with a retry_policy from sientia_do.temporal.policies.
  • Task queue isolation is deliberate: don't move activities between the orchestrator/alerts/reports worker activity lists without checking which queue actually needs them — each list in worker.py is scoped to what that workflow (+ its subworkflows) calls.
  • Namespaces: Temporal schedules span two namespaces, scouter and laborious (TEMPORAL_SCOUTER_NAMESPACE / TEMPORAL_LABORIOUS_NAMESPACE), handled inside TemporalManager.

External dependency

sientia-dataops-library (pinned via requirements.txt as a git dependency, currently @1.8.2) supplies sientia_do.observability.logger, sientia_do.observability.metrics_controller, sientia_do.notifications.handlers, sientia_do.temporal.policies, and sientia_do.temporal.activities.postgres.Postgres. It is a separate Aignosi repo — its version bump is a deliberate, explicit change, not incidental.

Tests

tests/ mirrors orchestrator/ (tests/orchestrator/activities/, tests/orchestrator/utils/, tests/orchestrator/workflows/...). Async tests use pytest-asyncio; coverage targets the orchestrator package. When testing Temporal workflows, follow the existing pattern in tests/orchestrator/workflows/test_orchestrator.py / test_alerts.py / test_reports.py (using Temporal's test env / activity mocking) rather than hitting real Temporal/Mongo/Redis/Postgres.

Ruff config notes (pyproject.toml)

Single quotes enforced by formatter. Notably ignored lint rules with reasons already documented inline: B023 (closures over loop vars needed for schedule-action assembly), BLE001 (blind except needed so activities can always notify on any error), N802/N806 (Temporal decorators/variables don't follow standard naming), S105/S106 (false-positive hardcoded-password matches).