Files
sientia-dataops-opc-ingestor/tests/unit
Eduardo Rios bf287a688c SIENTIAPDE-1975: align the gateway write path with the Laborious
- GW1: write commands (C2) carry only the server_id; ServerConfigResolver
  resolves the connection (command override, live pooled connection,
  connectors, opc-servers) with a 60 s cache and a 10 s negative cache.
- GW2: write_status keeps the worst outcome (ok < error < session_bad,
  pending/NULL replaced), same rule as the Laborious, built with SQLAlchemy
  Core (no SQL formatting).
- GW3: update_write_status never raises; outcome (updated, kept,
  row_not_found, invalid, error) logged and counted
  (opc_write_status_update_total); runs off the event loop.
- GW4: the reason of a failed write is logged; opc_write_status_by_model
  shows the last outcome; a bad timestamp is a failed write, not an
  exception.
- GW5: the NATS first connect gives up after 5 s (nats-py's defaults block
  the main loop for about 4 minutes while NATS is down); reconnection after
  it is unbounded; idle_sweep restarts a connection closed for good; stop()
  is safe on a closed connection.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-14 10:43:33 -03:00
..