Files
sientia-dataops-opc-ingestor/ingestor/config.py
Eduardo Rios 50578fdba8 SIENTIAPDE-1974: feat(read): slot v2 reads via SubscriptionEngine, OPC cert from MinIO
Swaps the legacy OpcManager read path for the gateway's SubscriptionEngine over
the shared OpcConnectionPool. The OPC client certificate now always comes from
MinIO + Mongo (CertProvider, Basic256Sha256) — no more certs/ shipped in the
Gitea repository, so a new version branch no longer breaks the reads.

- io/slots.py: parse_slot accepts slot v2 (names[]) and converts the legacy
  v1 (tag_name + topics; cert_path => use_security, path dropped), so gateway
  and Orchestrator can be deployed in any order.
- managers/server_reader.py: new per-server reader with the OpcManager
  interface the IngestorManager already drives (connect, create_subscription,
  subscribe, unsubscribe, check_cycles, check_opc_listenning, shutdown).
- IngestorManager owns the read path: lazy-MinIO CertProvider, the pool and a
  read DataSink, built without touching the network. Slots from Redis are
  normalized on lease and refresh; a malformed slot is notified and the last
  good config is kept.
- GatewayRuntime borrows the pool (writes/gRPC) instead of building it, and no
  longer closes it on stop: a Postgres/NATS failure can't stop the reads.
- pool: pin/unpin per active subscription so release_idle never evicts a
  subscribed connection; public evict() for lost servers / changed config.
- SubscriptionEngine pins on subscribe, unpins on unsubscribe, and drops a
  subscription locally even when the server-side delete fails.
- DataSink: model_id only written when the name has one, keeping v1 documents
  identical to the legacy ones.
- config: CERT_BUCKET default is the legacy streamlit-connectors bucket (D7).
- Removes OpcManager, its tests and scripts/generate-and-push-opc-cert.sh;
  README/CLAUDE.md document the MinIO certificate and the slot v2 format.

Tests: 218 unit tests pass; ruff check/format clean. Local end-to-end against
an asyncua server: v1 slot with two topics -> one doc per collection, legacy
doc shape, idle sweep keeps the subscription, lost-server shutdown and
re-initialization work.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-06 13:27:18 -03:00

49 lines
2.0 KiB
Python

"""Gateway-specific env config (NATS/gRPC/certs/write flags).
Separate from ingestor.py's inline os.getenv (Redis/Mongo/TTLs) — this module
covers only the new gateway wiring consumed by app.py in Task 18.
"""
from dataclasses import dataclass
from os import getenv
def _env_bool(name: str, default: bool) -> bool:
value = getenv(name)
if value is None:
return default
return value.strip().lower() in ('true', '1', 'yes')
@dataclass
class GatewayConfig:
nats_url: str = 'nats://localhost:4222'
nats_write_subject: str = 'opc.write'
nats_queue: str = 'gateway-writers'
grpc_enabled: bool = False
grpc_port: int = 50051
# Legacy frontend bucket the platform already provisions (SIENTIAPDE-1974 D7);
# the design's `sientia-dataops` bucket does not exist in the platform MinIO.
cert_bucket: str = 'streamlit-connectors'
cert_cache_dir: str = '/tmp/opc-certs' # noqa: S108 # nosec B108 - default is spec'd, overridable via env
write_timestamp: bool = True
write_quality: bool = True
write_min_pause_s: float = 0.0
idle_conn_max_s: float = 300.0
@classmethod
def from_env(cls) -> 'GatewayConfig':
return cls(
nats_url=getenv('NATS_URL', cls.nats_url),
nats_write_subject=getenv('NATS_WRITE_SUBJECT', cls.nats_write_subject),
nats_queue=getenv('NATS_QUEUE', cls.nats_queue),
grpc_enabled=_env_bool('GRPC_ENABLED', cls.grpc_enabled),
grpc_port=int(getenv('GRPC_PORT', cls.grpc_port)),
cert_bucket=getenv('CERT_BUCKET', cls.cert_bucket),
cert_cache_dir=getenv('CERT_CACHE_DIR', cls.cert_cache_dir),
write_timestamp=_env_bool('WRITE_TIMESTAMP', cls.write_timestamp),
write_quality=_env_bool('WRITE_QUALITY', cls.write_quality),
write_min_pause_s=float(getenv('WRITE_MIN_PAUSE_S', cls.write_min_pause_s)),
idle_conn_max_s=float(getenv('IDLE_CONN_MAX_S', cls.idle_conn_max_s)),
)