- write_timestamp/write_quality come from the command, then the server
document (connectors/opc-servers, read even when the reads have the
connection open, same 60 s cache), then the WRITE_TIMESTAMP/WRITE_QUALITY
env defaults.
- The quality comes from the command's `quality` (the prediction status:
Good/Bad/Uncertain, Good when absent); an unknown one is a bad_quality error.
- A server that refuses them (BadWriteNotSupported, e.g. Kepware) gets the
value written again alone and is remembered until restart: one warning and
opc_write_value_only_fallback_total per server.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- GW1: write commands (C2) carry only the server_id; ServerConfigResolver
resolves the connection (command override, live pooled connection,
connectors, opc-servers) with a 60 s cache and a 10 s negative cache.
- GW2: write_status keeps the worst outcome (ok < error < session_bad,
pending/NULL replaced), same rule as the Laborious, built with SQLAlchemy
Core (no SQL formatting).
- GW3: update_write_status never raises; outcome (updated, kept,
row_not_found, invalid, error) logged and counted
(opc_write_status_update_total); runs off the event loop.
- GW4: the reason of a failed write is logged; opc_write_status_by_model
shows the last outcome; a bad timestamp is a failed write, not an
exception.
- GW5: the NATS first connect gives up after 5 s (nats-py's defaults block
the main loop for about 4 minutes while NATS is down); reconnection after
it is unbounded; idle_sweep restarts a connection closed for good; stop()
is safe on a closed connection.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- config: GatewayConfig.certs_from_env() reads only CERT_BUCKET/CERT_CACHE_DIR;
IngestorManager uses it, so a malformed write/gRPC env var (GRPC_PORT,
WRITE_MIN_PAUSE_S, IDLE_CONN_MAX_S) can no longer stop the reads.
- certs: CertProvider raises CertificateNotConfiguredError with an actionable
message when no platform_certificates document exists; downloads once under
an asyncio.Lock, caches the paths, writes atomically (tmp + os.replace);
invalidate() forces a fresh download.
- pool: server_id normalized to str (1 and '1' share a session); warns when a
get() asks for other url/server_uri/use_security than the pooled client was
opened with (client reused, the slot config wins); invalidates the cert
cache when a secured connect fails.
- SubscriptionEngine: tracks nodes per subscription and forgets them on
unsubscribe (no more cycle alarms / tag count for removed tags), keeping
addresses still monitored by another slot.
- ServerReader.shutdown(evict) / IngestorManager.remove_server(evict): a
server that only left this pod's slots keeps the shared connection for
NATS writes/gRPC; lost servers and config changes still evict.
- IngestorManager warns once per server when a slot still sets
server_cert_path (server certificate pinning is no longer applied).
- slots: CONNECTION_FIELDS exported and reused by ServerReader.
Accepted, not changed: read metrics label server_name with the server_id
(same as the write path, which only knows the id); a malformed slot is
notified each lease attempt (alerts are deduplicated by notification_id).
Tests: 236 unit tests pass (+18); ruff clean; local e2e against an asyncua
server incl. slot moved (connection kept and reused by the write path) and
lost-server eviction/re-initialization.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Swaps the legacy OpcManager read path for the gateway's SubscriptionEngine over
the shared OpcConnectionPool. The OPC client certificate now always comes from
MinIO + Mongo (CertProvider, Basic256Sha256) — no more certs/ shipped in the
Gitea repository, so a new version branch no longer breaks the reads.
- io/slots.py: parse_slot accepts slot v2 (names[]) and converts the legacy
v1 (tag_name + topics; cert_path => use_security, path dropped), so gateway
and Orchestrator can be deployed in any order.
- managers/server_reader.py: new per-server reader with the OpcManager
interface the IngestorManager already drives (connect, create_subscription,
subscribe, unsubscribe, check_cycles, check_opc_listenning, shutdown).
- IngestorManager owns the read path: lazy-MinIO CertProvider, the pool and a
read DataSink, built without touching the network. Slots from Redis are
normalized on lease and refresh; a malformed slot is notified and the last
good config is kept.
- GatewayRuntime borrows the pool (writes/gRPC) instead of building it, and no
longer closes it on stop: a Postgres/NATS failure can't stop the reads.
- pool: pin/unpin per active subscription so release_idle never evicts a
subscribed connection; public evict() for lost servers / changed config.
- SubscriptionEngine pins on subscribe, unpins on unsubscribe, and drops a
subscription locally even when the server-side delete fails.
- DataSink: model_id only written when the name has one, keeping v1 documents
identical to the legacy ones.
- config: CERT_BUCKET default is the legacy streamlit-connectors bucket (D7).
- Removes OpcManager, its tests and scripts/generate-and-push-opc-cert.sh;
README/CLAUDE.md document the MinIO certificate and the slot v2 format.
Tests: 218 unit tests pass; ruff check/format clean. Local end-to-end against
an asyncua server: v1 slot with two topics -> one doc per collection, legacy
doc shape, idle sweep keeps the subscription, lost-server shutdown and
re-initialization work.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
main's requirements.txt unpins asyncua (PR #30), so CI installs 2.0.1,
where DataValue's field was renamed StatusCode_ -> StatusCode. The old
kwarg made every OPC write raise TypeError at runtime - masked locally
by a stale asyncua 1.0.6 in the dev conda env. Also uses ua.DateTime
(a datetime subclass) and ua.UInt32 to satisfy the new stricter types,
with no behavior change (verified via binary encode/decode round-trip).
- nats_consumer/grpc_server: annotate nc/sub/server attrs (were inferred
as None-only from __init__, breaking on the real assignment later).
- active_read: narrow on 'if names:' instead of the derived 'persisted'
bool so mypy sees names as non-Optional inside the publish_reading call.
- pyproject: exclude ingestor/proto/ (protoc/grpcio-tools output) from
mypy's file walk and skip following it as an import - it's generated,
not hand-maintained, and mypy can't see its runtime-built message classes.