Commit Graph

6 Commits

Author SHA1 Message Date
ecb055eefb SIENTIAPDE-1973
SIENTIAPDE-1973: Implement per-connector OPC client certificates and remove legacy read engine.
This update overhauls certificate management, transitioning from a single platform certificate to individual client certificates defined in the slot configuration. The CertProvider now downloads certificates from MinIO based on certificate_id, applying dynamic security policies (mode, policy) from the slot. The legacy READ_ENGINE=legacy option and OpcManager have been entirely removed, standardizing on the ServerReader with strict slot v2 enforcement. Write command resolution (ServerConfigResolver) now consistently uses connectors joined with opc_certificates. The CERT_BUCKET environment variable is no longer used.
2026-10-29 12:39:21 -03:00
Eduardo Rios
bf287a688c SIENTIAPDE-1975: align the gateway write path with the Laborious
- GW1: write commands (C2) carry only the server_id; ServerConfigResolver
  resolves the connection (command override, live pooled connection,
  connectors, opc-servers) with a 60 s cache and a 10 s negative cache.
- GW2: write_status keeps the worst outcome (ok < error < session_bad,
  pending/NULL replaced), same rule as the Laborious, built with SQLAlchemy
  Core (no SQL formatting).
- GW3: update_write_status never raises; outcome (updated, kept,
  row_not_found, invalid, error) logged and counted
  (opc_write_status_update_total); runs off the event loop.
- GW4: the reason of a failed write is logged; opc_write_status_by_model
  shows the last outcome; a bad timestamp is a failed write, not an
  exception.
- GW5: the NATS first connect gives up after 5 s (nats-py's defaults block
  the main loop for about 4 minutes while NATS is down); reconnection after
  it is unbounded; idle_sweep restarts a connection closed for good; stop()
  is safe on a closed connection.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-14 10:43:33 -03:00
Eduardo Rios
50578fdba8 SIENTIAPDE-1974: feat(read): slot v2 reads via SubscriptionEngine, OPC cert from MinIO
Swaps the legacy OpcManager read path for the gateway's SubscriptionEngine over
the shared OpcConnectionPool. The OPC client certificate now always comes from
MinIO + Mongo (CertProvider, Basic256Sha256) — no more certs/ shipped in the
Gitea repository, so a new version branch no longer breaks the reads.

- io/slots.py: parse_slot accepts slot v2 (names[]) and converts the legacy
  v1 (tag_name + topics; cert_path => use_security, path dropped), so gateway
  and Orchestrator can be deployed in any order.
- managers/server_reader.py: new per-server reader with the OpcManager
  interface the IngestorManager already drives (connect, create_subscription,
  subscribe, unsubscribe, check_cycles, check_opc_listenning, shutdown).
- IngestorManager owns the read path: lazy-MinIO CertProvider, the pool and a
  read DataSink, built without touching the network. Slots from Redis are
  normalized on lease and refresh; a malformed slot is notified and the last
  good config is kept.
- GatewayRuntime borrows the pool (writes/gRPC) instead of building it, and no
  longer closes it on stop: a Postgres/NATS failure can't stop the reads.
- pool: pin/unpin per active subscription so release_idle never evicts a
  subscribed connection; public evict() for lost servers / changed config.
- SubscriptionEngine pins on subscribe, unpins on unsubscribe, and drops a
  subscription locally even when the server-side delete fails.
- DataSink: model_id only written when the name has one, keeping v1 documents
  identical to the legacy ones.
- config: CERT_BUCKET default is the legacy streamlit-connectors bucket (D7).
- Removes OpcManager, its tests and scripts/generate-and-push-opc-cert.sh;
  README/CLAUDE.md document the MinIO certificate and the slot v2 format.

Tests: 218 unit tests pass; ruff check/format clean. Local end-to-end against
an asyncua server: v1 slot with two topics -> one doc per collection, legacy
doc shape, idle sweep keeps the subscription, lost-server shutdown and
re-initialization work.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-06 13:27:18 -03:00
PedroHMCosme
79258658bc style: ruff format (new quality gate check picked up from main) 2026-09-22 11:29:41 -03:00
PedroHMCosme
3f413f8d6f fix(gateway): app survives runtime init failure; dedupe NATS-down notifications; fix stale slot_lookup note 2026-07-15 14:17:21 -03:00
PedroHMCosme
391268776c feat(gateway): wire engines+adapters via GatewayRuntime (write/gRPC live; subscription v2 gated on 1974)
GatewayRuntime builds and owns the F4 object graph (CertProvider/pool ->
WriteEngine/NatsWriteConsumer -> ActiveReadEngine -> optional GrpcServer),
reusing the existing ingestor's logger/notification_handler/metrics_controller
and DataManager (CertProvider shares its Mongo connection instead of opening
a second one). app.py starts it after prepare_ingestor, sweeps idle OPC
connections each loop iteration, and stops it on shutdown. A NATS connect
failure at startup is logged/notified but never crashes the app -- the read
path keeps working and idle_sweep() retries the consumer start.

ingestor.py needed no changes: data_manager is already reachable via
ingestor.ingestor_manager.data_manager.

Also documents the new MinIO/Postgres env vars this wiring reads (via
sientia_do's build_postgres_config for Postgres) in .env.example, and
updates test_app.py's fixture to mock GatewayConfig/GatewayRuntime so the
existing app tests keep exercising only what they mocked before.
2026-07-15 13:51:18 -03:00