feat(gateway): wire engines+adapters via GatewayRuntime (write/gRPC live; subscription v2 gated on 1974)

GatewayRuntime builds and owns the F4 object graph (CertProvider/pool ->
WriteEngine/NatsWriteConsumer -> ActiveReadEngine -> optional GrpcServer),
reusing the existing ingestor's logger/notification_handler/metrics_controller
and DataManager (CertProvider shares its Mongo connection instead of opening
a second one). app.py starts it after prepare_ingestor, sweeps idle OPC
connections each loop iteration, and stops it on shutdown. A NATS connect
failure at startup is logged/notified but never crashes the app -- the read
path keeps working and idle_sweep() retries the consumer start.

ingestor.py needed no changes: data_manager is already reachable via
ingestor.ingestor_manager.data_manager.

Also documents the new MinIO/Postgres env vars this wiring reads (via
sientia_do's build_postgres_config for Postgres) in .env.example, and
updates test_app.py's fixture to mock GatewayConfig/GatewayRuntime so the
existing app tests keep exercising only what they mocked before.
This commit is contained in:
PedroHMCosme
2026-07-15 13:51:18 -03:00
parent ff605eea93
commit 391268776c
5 changed files with 371 additions and 0 deletions

View File

@@ -8,6 +8,8 @@ from time import time
from prometheus_client import start_http_server
import ingestor.metrics as metrics
from ingestor.config import GatewayConfig
from ingestor.gateway_runtime import GatewayRuntime
from ingestor.ingestor import Ingestor
exit_signal = Event()
@@ -48,10 +50,27 @@ async def main(): # NOSONAR
exit_signal.set()
ingestor.logger.info('Ingestor prepared. Starting main loop.')
# Gateway write/active-read/gRPC wiring (Task 18). Only built if prepare_ingestor
# got far enough to have a data_manager (needed by CertProvider/DataSink) --
# skipped entirely if prepare failed before that point.
runtime: GatewayRuntime | None = None
if ingestor.ingestor_manager is not None:
runtime = GatewayRuntime(
config=GatewayConfig.from_env(),
data_manager=ingestor.ingestor_manager.data_manager,
logger=ingestor.logger,
notification_handler=ingestor.notification_handler,
metrics_controller=ingestor.metrics_controller,
metadata=ingestor.metadata,
)
await runtime.start()
while not exit_signal.is_set(): # NOSONAR
start_time = time() # Start loop timer
try:
await ingestor.loop()
if runtime is not None:
await runtime.idle_sweep()
metrics.APP_LOOP_COUNT.labels(pod_id=POD_ID).inc() # Increment loop counter
# Use asyncio.sleep instead of exit_signal.wait for better async compatibility
@@ -70,6 +89,8 @@ async def main(): # NOSONAR
duration = time() - start_time
metrics.APP_LOOP_DURATION.labels(pod_id=POD_ID).observe(duration)
if runtime is not None:
await runtime.stop()
await ingestor.shutdown()
metrics.APP_UP.labels(pod_id=POD_ID).set(0) # Mark app as DOWN

149
ingestor/gateway_runtime.py Normal file
View File

@@ -0,0 +1,149 @@
"""GatewayRuntime (Task 18 F4 capstone): builds and owns the write/active-read/gRPC
object graph and wires it into the app's lifecycle.
Reuses the existing ingestor's logger/notification_handler/metrics_controller and
its already-connected DataManager (so CertProvider shares the existing Mongo
connection instead of opening a second one -- MongoDBRepository.find_one has the
exact (collection_name, filters, metadata) signature CertProvider.fetch calls).
# ponytail: subscription v2 swap + scheduled_tick wiring happen at 1974
# integration; when swapping, build ONE SubscriptionEngine per OPC server (its
# non_receive_count is engine-wide -- see plan ledger F1 carry-forward).
"""
from os import getenv
from sientia_do.notifications.handlers import CoreNotificationHandler as NotificationHandler
from sientia_do.notifications.models import NotificationLevel
from sientia_do.observability.logger import Logger
from sientia_do.observability.metrics_controller import MetricsController
from sientia_do.observability.sientia_monitoring import SientiaMonitoring
from sientia_do.repository.minio_repository import MinioRepository
from sientia_do.temporal.activities.postgres import Postgres
from sientia_do.utils.connectors_config import build_postgres_config
from ingestor.adapters.grpc_server import GrpcServer
from ingestor.adapters.nats_consumer import NatsWriteConsumer
from ingestor.config import GatewayConfig, _env_bool
from ingestor.connection.certs import CertProvider
from ingestor.connection.pool import OpcConnectionPool
from ingestor.engines.active_read import ActiveReadEngine
from ingestor.engines.write import WriteEngine
from ingestor.io.data_sink import DataSink
from ingestor.managers.data_manager import DataManager
class GatewayRuntime(SientiaMonitoring):
"""Owns the gateway write/active-read/gRPC object graph. Resilient to NATS
being unreachable at startup: the read path (existing subscription loop,
gRPC on-demand reads) must keep working even if the write path can't
connect yet -- so a NATS connect failure is logged/notified, not raised,
and retried from `idle_sweep()` on each main-loop iteration."""
def __init__(
self,
config: GatewayConfig,
data_manager: DataManager,
logger: Logger,
notification_handler: NotificationHandler,
metrics_controller: MetricsController,
metadata: dict | None = None,
):
SientiaMonitoring.__init__(self, logger, notification_handler, metrics_controller)
self.config = config
self.metadata = metadata or {}
self._nats_started = False
minio = MinioRepository(
endpoint=getenv('MINIO_ENDPOINT', 'localhost:9000'),
access_key=getenv('MINIO_ACCESS_KEY', 'minioadmin'),
secret_key=getenv('MINIO_SECRET_KEY', 'minioadmin'),
secure=_env_bool('MINIO_SECURE', True),
bucket=config.cert_bucket,
logger=logger,
notification_handler=notification_handler,
metrics_controller=metrics_controller,
)
cert_provider = CertProvider(
mongo=data_manager.mongo_repository,
minio=minio,
cache_dir=config.cert_cache_dir,
bucket=config.cert_bucket,
metadata=self.metadata,
)
self.pool = OpcConnectionPool(cert_provider, logger, notification_handler, metrics_controller)
postgres = Postgres(
**build_postgres_config(),
logger=logger,
notification_handler=notification_handler,
metrics_controller=metrics_controller,
)
self.sink = DataSink(data_manager, postgres)
self.write_engine = WriteEngine(
self.pool,
self.sink,
logger,
notification_handler,
metrics_controller,
write_timestamp=config.write_timestamp,
write_quality=config.write_quality,
min_pause_s=config.write_min_pause_s,
)
self.nats_consumer = NatsWriteConsumer(
config.nats_url,
self.write_engine,
logger,
subject=config.nats_write_subject,
queue=config.nats_queue,
)
self.active_read = ActiveReadEngine(
self.pool, self.sink, logger, notification_handler, metrics_controller
)
# slot_lookup=None for now: address -> names resolution needs slot v2
# (1974); until then ReadTag responses just aren't persisted.
self.grpc_server = (
GrpcServer(self.active_read, logger, port=config.grpc_port, slot_lookup=None)
if config.grpc_enabled
else None
)
async def start(self) -> None:
await self._start_nats()
if self.grpc_server is not None:
await self.grpc_server.start()
self.logger.info(
f'GatewayRuntime started: nats_started={self._nats_started} '
f'grpc_enabled={self.grpc_server is not None}'
)
async def stop(self) -> None:
if self.grpc_server is not None:
await self.grpc_server.stop()
if self._nats_started:
await self.nats_consumer.stop()
self._nats_started = False
await self.pool.close_all()
async def idle_sweep(self) -> None:
await self.pool.release_idle(self.config.idle_conn_max_s)
if not self._nats_started:
await self._start_nats()
async def _start_nats(self) -> None:
if self._nats_started:
return
try:
await self.nats_consumer.start()
self._nats_started = True
except Exception as e:
self.logger.error(f'GatewayRuntime: failed to start NATS write consumer: {e}')
await self.send_notification_async(
metadata=self.metadata,
notification_id='GATEWAY_NATS_CONSUMER_START_FAILED',
message=f'Failed to start NATS write consumer: {e}',
block='gateway_runtime',
level=NotificationLevel.ERROR,
)