The probes only check app_up, which was set to 1 when the metrics server started, before install_runtime. A pod that would fail the guard could turn Ready first, so a rollout would remove the old pod. app_up now goes to 1 right after the guard. Also: copy sys.modules keys before iterating, raise the sientia_model floor to the runtime's >=0.14.0, pin the same runtime versions in requirements-local.txt, test that the snapshot is taken before the install and the real importlib.metadata path, and document the boot failure in README and CLAUDE.md.
23 lines
696 B
Plaintext
23 lines
696 B
Plaintext
temporalio==1.23.0
|
|
psycopg2-binary==2.9.11
|
|
sqlalchemy==2.0.50
|
|
boto3==1.42.70
|
|
botocore==1.42.70
|
|
sientia_do>=1.12.2
|
|
sientia_model>=0.14.0
|
|
prometheus-client==0.23.1
|
|
beautifulsoup4==4.12.3
|
|
evidently==0.6.7
|
|
jsonschema==4.26.0
|
|
# Same versions as the plugin runtimes (model-plugin-factory runtime/basic.yaml and xgboost.yaml).
|
|
# The worker imports these before install_runtime; if the runtime installed a different version,
|
|
# the old code would stay in memory, so the worker refuses to boot (SIENTIAPDE-2214).
|
|
# Changing a runtime pin means changing it here and in requirements-local.txt too.
|
|
mlflow==3.8.1
|
|
pathspec==1.0.4
|
|
pandas==2.3.3
|
|
cloudpickle==3.1.2
|
|
scikit-learn==1.8.0
|
|
joblib==1.5.3
|
|
rich==14.3.2
|